X-Ban®

 ISO9001-2000

Test Parameters

 The graphs on the right illustrate the

performance of X-Ban® High Performance

Attenuating Materials. Tests were

performed in accordance with IEC

61331-1:1994 International Standard for

measuring the attenuation of protective

devices against X-radiation.

Performance

 The graphs on the right illustrate the

performance of X-Ban® high performance

Attenuating Materials. RayShield X-Ban®

is a superior performance X-ray attenuating

material, manufactured under strict Quality

Assurance Guidelines. The technical

information given in this data sheet is

accurate to the best of our knowledge

and is intended as a guide. AADCO

Medical, Inc. guarantees/certifies materials

supplied to given lead equivalent values

and production specification criteria within

acceptable tolerances. Customers/end

users are advised to test materials under

their own conditions of use to satisfy

themselves as to their suitability.

Health & Safety

 The lead/lead-free metal particles are firmly

bound within the polymeric structure ensur-

ing that oxidisation of the lead/lead-free

metal and therefore absorption through the

skin is not possible. However, ingestion of

the materials would have a harmful affect

and should be avoided.

Fire Precautions & Waste Disposal

 Due to the high content of metallic lead

contained in materials other than those

designated Lead Free, any waste material

should be disposed of by recycling by prior

arrangement with AADCO Medical, Inc.

or by disposal in registered landfill sites in

accordance with local and federal landfill

regulations.

Leaded material should not be disposed of

by incineration and use of self-contained

breathing apparatus is recommended if the

sheeting is ignited by an internal fire.

Lead-free waste material is environmen-

tally friendly and may be recycled by prior

arrangement with AADCO Medical, Inc. or

disposed of via standard disposal methods.

No special or registered disposal/landfill

sites are required. No toxic ingredients.

AADCO Medical will accept the return of

all materials listed herein, from our custom-

ers, by prior arrangement, for environmen-

tally friendly recycling.

Flammability

 These materials will burn in the presence

of fire but are self-extinguishing when the

flame is removed. Extinguishing Media: Dry

chemical, carbon-dioxide foam or water.

 X-Ban® SuperLight Performance

in mm of Lead Equivalence

0.55

0.50

0.45

0.40

0.35

mm of Lead Equivalence

0.30

0.25

0.20

60 KVP

80 KVP

100 KVP

110 KVP

120 KVP

.5mm X-Ban® SuperLight

.35mm X-Ban® SuperLight

.25mm X-Ban® SuperLight

Test Energy Levels

.5mm X-Ban® LightWeight

.35mm X-Ban® LightWeight

.25mm X-Ban® LightWeight

X-Ban® LightWeight Performance

in mm of Lead Equivalence

0.55

0.50

0.45

0.40

0.35

mm of Lead Equivalence

0.30

0.25

0.20

60 KVP

80 KVP

100 KVP

110 KVP

120 KVP

Test Energy Levels

X-Ban® Flexible X-ray Attenuating Materials Performance Data

   .5mm X-Ban® LeadFree

.35mm X-Ban® LeadFree

.25mm X-Ban® LeadFree

X-Ban® LeadFree Performance

in mm of Lead Equivalence

0.55

0.50

0.45

0.40

0.35

mm of Lead Equivalence

0.30

0.25

0.20

60 KVP

80 KVP

100 KVP

110 KVP

120 KVP

Test Energy Levels